CrossLab Supplies for Shimadzu GC Systems
Agilent CrossLab  

CrossLab is more than supplies.

CrossLab is a growing portfolio of supplies critical to instrument performance and productivity, manufactured to perform seamlessly with a variety of analytical instruments in your lab, regardless of make or model.

Browse this collection page for Shimadzu instruments to find a comprehensive selection of products to use across your lab.

 

Agilent Crosslab Autosampler Syringes for Shimadzu GC Systems

With a broad selection of syringes for auto injection, CrossLab autosampler syringes provide what you need for accurate and effective sampling. CrossLab syringes meet all fit, form, and function criteria for specific autosampler model. Agilent delivers more value in every autosampler syringe.
• Lot number printed directly on the barrel with a corresponding Certificate of Conformance
• Illuminating backing strip, for effortless viewing of the volume scale
• Environmentally friendly packaging and improved design that reduces waste
• Individually sealed packaging for contaminant-free use right out of the box

background-color: #ededed;
ModelVolume (µL) Description Needle Gauge/Length
(mm)/Tip
Syringe Replacement Needle (2/pk)
AOC-14
AOC-17
AOC-20
5 Fixed needle 23/42/cone tip 8001-0001  
10 Removable needle 23/42/cone tip 8001-0004 8001-0005
Removable needle 26/42/cone tip 8001-0006 8001-0007
50 Fixed needle 23/42/cone tip 8001-0002  
250 Fixed needle, gas tight 23/42/cone tip 8001-0003  

Agilent Crosslab Capillary Column Ferrules for Shimadzu GC Systems


We offer graphite, vespel/graphite, and vespel CrossLab ferrules. The ideal ferrule provides a leak-free seal, accommodates various column outer diameters, seals with minimum torque, withstands temperature cycling, and does not stick to the column or fittings. For optimum performance, ferrules should be replaced every time the column is replaced and when performing column maintenance.
  • Graphite ferrules provide an easy-to-use stable seal, boast a high temperature limit, and can be removed easily
  • Vespel/graphite ferrules are mechanically robust and maintain a long lifetime
  • Vespel ferrules are mechanically robust, maintain a long lifetime, and can be reused or remove easily
Model Fitting Size (in.) Ferrule ID (mm) Column ID (mm) Hole Unit 85% Vespel/
15% Graphite
Graphite
2010, 2010 Plus,
2014, 17A, 14A
1/16 0.4 0.25 1 10/pk   8001-0211
1/16 0.5 0.32 1 10/pk   8001-0212
1/16 0.8 0.53 1 10/pk   8001-0213
QP5000/5050
Standard MS
1/16 0.3 0.18 or smaller 1 10/pk 8001-0224  
1/16 0.4 0.25 1 10/pk 8001-0221  
1/16 0.5 0.32 1 10/pk 8001-0222  
1/16 0.8 0.53 1 10/pk 8001-0223  
QP2010 1/16 0.4 0.25 1 10/pk 8010-0310  
1/16 0.4 0.25 2 10/pk 8010-0312  
1/16 0.5 0.32 1 10/pk 8010-0311  
1/16 0.8 0.53 1 10/pk 8010-0313  
Model Fitting Size (in.) Ferrule ID (in.) Column ID (in.) Hole Unit 85% Vespel/
15% Graphite
Graphite
QP5000/5050
Standard MS
1/4 1/4 1/4 1 10/pk 8010-0314  
QP5000/5050
Wide Bore MS
1/16 1/16 1/16 1 10/pk 8010-0315  
QP2010 1/16 1/16 1/16 1 10/pk 8010-0315  
17A 5mm 5mm 5mm OD 1 10/pk 8001-0214  

Agilent Crosslab Column Nuts for Shimadzu Systems

CrossLab is a growing portfolio of supplies critical to instrument performance and productivity, manufactured to perform seamlessly with a variety of analytical instruments in your lab, regardless of make or mode. Agilent now offers CrossLab Column Nuts to suit your needs.

• CrossLab column nuts to seemlessly fit with your instrument
Description Unit Part Number
Column nut, slotted, 6-sided 2/pk 8001-0311
Column nut, no slot, 6-sided 2/pk 8001-0312

Agilent CrossLab Inlet Liners for Shimadzu GC Systems

Liners are the centerpiece of the inlet system where sample is vaporized and mixed with the carrier gas. CrossLab GC inlet liners have the perfect mix of liner configurations and chemistries to solve your application challenges. Choose from split, splitless, PTV, and other inlet liner designs in either the new, innovative Ultra Inert deactivation or Agilent's popular original deactivation.

With part number and lot number silk screened on CrossLab liners, identification and re-ordering has never been easier.

• Perfect mix of liner configurations and chemistries to solve application challenges
• CrossLab Ultra Inert Liners offer reproducibility, robustness, and reliability
• CrossLab Ultra Inert Liners are delivered in Agilent's exclusive Touchless packaging
• Agilent original deactivation is recommended for everyday analysis

Liners for 2014 Systems
Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Agilent Ultra Inert Deactivation Agilent
Original Deactivation
Splitless Liners
Straight-through 2.6 5.0 95 500 5/pk 8001-0151 8001-0101
Direct Liners
For 0.53 mm ID column 2.6 5.0 95 500 5/pk 8001-0152 8001-0102
Liners for 2010 and 2010 Plus Systems
Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Agilent Ultra Inert Deactivation Agilent
Original Deactivation
Split/Splitless Liners
Single taper 3.4 5.0 95   5/pk 8001-0154 8001-0104
Splitless Liners
Straight-through 2.6 5.0 95 500 5/pk 8001-0151 8001-0101
Split Liners
Straight-through 3.4 5.0 95 860 5/pk 8001-0153 8001-0103
Liners for 17A Systems
Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Agilent Ultra Inert Deactivation Agilent
Original Deactivation
Splitless Liners
Straight-through 2.6 5.0 95 500 5/pk 8001-0151 8001-0101
Split Liners
Straight-through 3.4 5.0 95 860 5/pk 8001-0153 8001-0103
Direct Liners
For 0.53 mm ID column 2.6 5.0 95 450 5/pk 8001-0152 8001-0102
Liners for 14 Systems
Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Agilent Ultra Inert Deactivation Agilent
Original Deactivation
Split/Splitless Liners
2.0 mm middle gooseneck 3.4 5.0 99 850 5/pk 8001-0155 8001-0105

Agilent Crosslab Liner O-rings for Shimadzu GC Systems

Fluoroelastomer and Graphite O-rings
CrossLab fluoroelastomer or graphite liner o-rings aid in sealing the inlet liner. Fluoroelastomer O-rings are ready for chromatographic use and feature a proprietary two-step cleaning and conditioning process which eliminates out-gassing of contaminants, a plasma-treatement for a non-stick, contaminant free surface, and a novel dial package that conveniently delivers on clean O-ring at a time.
• Liners are sealed in the inlet with Fluoroelastomer or graphite O-rings
• Graphite O-rings are used when inlet temperatures exceed 350°C
• Fluoroelastomer O-rings are easier to replace than graphite O-rings, which deform and flake apart more easily

Description Unit Part Number
Liner O-ring, non-stick fluoroelastomer 10/pk 8001-0201
Liner O-ring, graphite, split 10/pk 8001-0202
Liner O-ring, graphite, splitless 10/pk 8001-0203