logo
Agilent Crosslab   Agilent Crosslab guide
    Crosslab Section Guide (PDF)
CrossLab Supplies for Thermo GC Systems
Agilent CrossLab  

CrossLab is more than supplies.

CrossLab is a growing portfolio of supplies critical to instrument performance and productivity, manufactured to perform seamlessly with a variety of analytical instruments in your lab, regardless of make or model.

Browse this collection page for Thermo instruments to find a comprehensive selection of products to use across your lab.

 

Agilent Crosslab Autosampler Syringes for Thermo GC Systems

With a broad selection of syringes for auto injection, CrossLab autosampler syringes provide what you need for accurate and effective sampling. CrossLab syringes meet all fit, form, and function criteria for specific autosampler model. Agilent delivers more value in every autosampler syringe.
• Lot number printed directly on the barrel with a corresponding Certificate of Conformance
• Illuminating backing strip, for effortless viewing of the volume scale
• Environmentally friendly packaging and improved design that reduces waste
• Individually sealed packaging for contaminant-free use right out of the box

Model Volume (µL) Description Needle Gauge/ Length(mm)/Tip Syringe Replacement Plunger or Needle
TriPlus, AS3000 0.5 Plunger-in-needle 23/50/cone tip 8010-0355 8010-0367
Needle Plunger kit
TriPlus 5 Fixed needle 26/50/cone tip 8010-0353  
TriPlus, AS3000, AS2000, AS200, AS800 10 Fixed needle 23/50/cone tip 8010-0351  
Fixed needle 26/50/cone tip 8010-0352  
Fixed needle 25/50/cone tip 8002-0003  
TriPlus, AS2000 Fixed needle 23/80/cone tip 8002-0002  
Fixed needle 26/80/cone tip 8002-0001  
TriPlus, AS2000, AS200, AS800 100 Fixed needle,
gas tight
23/50/cone tip 8010-0354 8010-0368
Plunger
TriPlus, AS2000 Removable needle, gas tight 23/50/side 8002-0004 8002-0005
Needle

Agilent Crosslab Capillary Column Ferrules for Thermo GC Systems


We offer graphite, vespel/graphite, and vespel CrossLab ferrules. The ideal ferrule provides a leak-free seal, accommodates various column outer diameters, seals with minimum torque, withstands temperature cycling, and does not stick to the column or fittings. For optimum performance, ferrules should be replaced every time the column is replaced and when performing column maintenance.
  • Graphite ferrules provide an easy-to-use stable seal, boast a high temperature limit, and can be removed easily
  • Vespel/graphite ferrules are mechanically robust and maintain a long lifetime
  • Vespel ferrules are mechanically robust, maintain a long lifetime, and can be reused or remove easily
Model Fitting Size (in.) Ferrule ID (mm) Column ID (mm) Hole Unit 85% Vespel/
15% Graphite
Graphite
Trace/Focus
Injectors/Detectors
(not for GC/MS
Interface)
M4 0.3 0.18 or smaller 1 10/pk   8002-0211
M4 0.4 0.25 1 10/pk   8002-0212
M4 0.5 0.32 1 10/pk   8002-0213
M4 0.8 0.53 1 10/pk   8002-0214
Injectors/Detectors 1/16 0.4 0.25 1 10/pk 8002-0220 8002-0215
1/16 0.5 0.32 1 10/pk 8002-0221 8002-0216
1/16 0.8 0.53 1 10/pk 8002-0222 8002-0217
Any GC/MS Interface 1/16 0.4 0.25 1 10/pk 8010-0310  
1/16 0.5 0.32 1 10/pk 8010-0311  

Agilent Crosslab Column Nuts for Thermo Systems

CrossLab is a growing portfolio of supplies critical to instrument performance and productivity, manufactured to perform seamlessly with a variety of analytical instruments in your lab, regardless of make or mode. Agilent now offers CrossLab Column Nuts to suit your needs.

• CrossLab column nuts to seemlessly fit with your instrument
Description Unit Part Number
Column nut, stainless steel, split/splitless injector, 2/pk 8002-0311
Column nut, brass, used with ferrules 8002-0220, 8002-0221, 8002-0222 2/pk 8002-0312

Agilent CrossLab Inlet Liners for Thermo GC Systems

Liners are the centerpiece of the inlet system where sample is vaporized and mixed with the carrier gas. CrossLab GC inlet liners have the perfect mix of liner configurations and chemistries to solve your application challenges. Choose from split, splitless, PTV, and other inlet liner designs in either the new, innovative Ultra Inert deactivation or Agilent's popular original deactivation.

With part number and lot number silk screened on CrossLab liners, identification and re-ordering has never been easier.

• Perfect mix of liner configurations and chemistries to solve application challenges
• CrossLab Ultra Inert Liners offer reproducibility, robustness, and reliability
• CrossLab Ultra Inert Liners are delivered in Agilent's exclusive Touchless packaging
• Agilent original deactivation is recommended for everyday analysis

Description ID (mm) OD (mm) Length (mm) Volume (µL) Unit Agilent Ultra Inert Deactivation Agilent
Original Deactivation
Splitless Liners
Single taper 5.0 8.0 105 1750 5/pk 8002-0153 8002-0103
Straight 3.0 8.0 105 750 5/pk 8002-0152 8002-0102
Single taper 3.0 8.0 105   5/pk 8002-0154 8002-0104
Split Liners
Straight 5.0 8.0 105 2000 5/pk 8002-0151 8002-0101
PTV Liners
Straight 1.75 2.75 120 300 5/pk   8002-0105

Agilent Crosslab Liner O-rings for Thermo GC Systems

Fluoroelastomer and Graphite O-rings
CrossLab fluoroelastomer or graphite liner o-rings aid in sealing the inlet liner. Fluoroelastomer O-rings are ready for chromatographic use and feature a proprietary two-step cleaning and conditioning process which eliminates out-gassing of contaminants, a plasma-treatement for a non-stick, contaminant free surface, and a novel dial package that conveniently delivers on clean O-ring at a time.
• Liners are sealed in the inlet with Fluoroelastomer or graphite O-rings
• Graphite O-rings are used when inlet temperatures exceed 350°C
• Fluoroelastomer O-rings are easier to replace than graphite O-rings, which deform and flake apart more easily

Description Unit Part Number
Liner O-ring, non-stick fluoroelastomer 10/pk 8010-0401
Liner O-ring, non-stick fluoroelastomer sintered liner 10/pk 8002-0201
Liner O-ring, graphite, 8 mm OD 2/pk 8002-0203
Liner O-ring, graphite, programmed temperature vaporization 2/pk 8001-0204