Skip to Store Area:

ESSLAB logo

Visiferm DO

Visiferm DO

HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor.

Optical oxygen measurement

Combined in the VISIFERM™ sensor shaft are: high-temperature resistant optical electronics, microprocessor, 4 to 20 mA analog output, digital RS 485 interface with ModBus protocol, and ECS interface. The Electro-Chemical Sensor (ECS) interface allows VISIFERM™ DO to be connected to existing classical measurement amplifiers designed for sterilizable oxygen sensors, such as the HAMILTON OXYFERM™. Use of the 4 to 20 mA analog output or the digital RS 485 interface (both integrated into the 12 mm shaft) makes an external measurement amplifier unnecessary, allowing measurement signals to be fed directly into a process control system.

Clear favourite in comparison

HAMILTON has successfully manufactured steam-sterilizable, autoclavable, CIP-compatible sensors for pH, oxidation/reduction, conductivity, and oxygen measurement
for many years. These classical oxygen sensors are based, as is common in the industry, on Clark Cell technology, in which oxygen diffuses through a membrane and is reduced electrochemically on a precious metal. The electrons involved in this process generate a very small current (nanoamperes) which is converted to an oxygen measurement signal by a measurement amplifier. Sensors such as these have served well for decades, but have their limitations.

VISIFERM™ DO optical sensors demonstrate a number of substantial advantages. This is because users of the VISIFERM™ DO receive more than just a sensor based on a new measurement principle. VISIFERM™ DO is a symbiosis of sensor and measurement amplifier—an intelligent sensor.

Application fields

VISIFERM™ DO sensors have been evaluated
in a variety of applications:

Biotechnology

VISIFERM™ DO sensors are developed to be steam sterilized and autoclaved without difficulty.  CIP cleaning is also tolerated very well. These properties, along with the standard design form of a classical 12 mm sensor with PG 13.5 thread, make VISIFERM™ DO superior for use in fermenters and similar demanding applications.

Breweries

VISIFERM™ DO is already being used to monitor carbon dioxide recovery, and is finding further application in the wort tank. Installations in the area of beer and beverage bottle filling are still in various test runs.

Cooling water cycles

Found in power plants and other applications for trace measurements

Gas monitoring applications depend on the composition of specific samples.

 

9 Item(s) Show per page
Sort by: Position| Name| Price| Manufacturer
Hamilton USB-ModBus RS 485 Converter
Manufacturer: Hamilton
£ 0.00
Cat no: 242411
Call for price
Connects the VISIFERMTM DO to a PC with USB port. Learn More
Hamilton VISICAL
Manufacturer: Hamilton
£ 0.00
Cat no: 242410
Call for price
Simplifies air and zero point calibration when using the 4 to 20 mA interface, or when precalibrating the sensor in a laboratory. It also displays overall sensor status, and indicates when a Sensor Cap needs to be replaced soon. Learn More
Hamilton VISIFERM DO 120 mm (Electrochemical Sensor Mode)
Manufacturer: Hamilton
£ 0.00
Cat no: 242450-02
Call for price
HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor. Learn More
Hamilton VISIFERM DO 160 mm (Electrochemical Sensor Mode)
Manufacturer: Hamilton
£ 0.00
Cat no: 242451-02
Call for price
HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor. Learn More
Hamilton VISIFERM DO 225 mm (Electrochemical Sensor Mode)
Manufacturer: Hamilton
£ 0.00
Cat no: 242452-02
Call for price
HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor. Learn More
Hamilton VISIFERM DO 325 mm (Electrochemical Sensor Mode)
Manufacturer: Hamilton
£ 0.00
Cat no: 242453-02
Call for price
HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor. Learn More
Hamilton VISIFERM DO 425 mm (Electrochemical Sensor Mode)
Manufacturer: Hamilton
£ 0.00
Cat no: 242454-02
Call for price
HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process and pH electrodes and classical sterilizable oxygen sensors. VISIFERM DO optical sensors demonstrate a number of substantial advantages because of a symbiosis of sensor and measurement amplifier- an intelligent sensor. Learn More
Hamilton VISIFERM Power Adapter
Manufacturer: Hamilton
£ 220.00
Cat no: 242413
Add to Cart
Connects VISIFERMTM DO in ECS mode to the cable of classical sterilizable oxygen sensor with four-pole plug (D4, T82) such as HAMILTON’s OXYFERM FDA. Includes a wall plug power supply. Learn More
Hamilton Visiferm Sensor Cap
Manufacturer: Hamilton
£ 0.00
Cat no: 242427
Call for price
Visiferm Sensor Cap
With VISIFERMTM, there is only one consumable. Under normal conditions, even with frequent steam sterilizing, autoclaving, and CIPs, the Sensor Cap has a lifetime of more than one year. Learn More
9 Item(s) Show per page